1P-LSD 100mcg Blotters
€23.75 – €299.00Price range: €23.75 through €299.00
Product Short Description
⚠️ For Research Purposes Only. Not for human or veterinary use. Not for clinical, diagnostic, or consumptive applications.
1P-LSD 100mcg Blotters is a brandless, generic lysergamide research chemical with ≥98% purity, supplied for analytical laboratory applications. This high-purity compound serves as a reference standard in controlled research settings. For research use only. Not for human or veterinary use. Not for clinical, diagnostic, or consumptive applications.
Buy 1P-LSD 100mcg Blotters Europe
Product Overview
1P-LSD (1-Propionyl-d-lysergic acid diethylamide, CAS 2349352-11-2) supplies researchers with a high-purity N1-acyl lysergamide reference standard for serotonin receptor pharmacology research, forensic toxicology analytical method development, and lysergamide structure-activity relationship studies within controlled laboratory environments. Researchers looking to buy 1P-LSD for laboratory use will find UltraRawz’s HPLC-verified blotter and solution formats suitable for 5-HT₂A and 5-HT₂B receptor binding studies, LC-MS/MS analytical method development, N1-acyl lysergamide prodrug hydrolysis characterization, and comparative pharmacological profiling across the expanding lysergamide compound class. 1P-LSD is one of several N1-acyl LSD analogues that have attracted significant research interest following their detection in NPS monitoring programs — alongside 1cP-LSD, 1B-LSD, 1V-LSD, and 1D-LSD — creating sustained demand for authenticated reference standards from forensic and pharmacology research programs worldwide. For research use only. Not for human or veterinary use. Not for clinical, diagnostic, or consumptive applications.
1P-LSD differs from the parent lysergamide LSD (lysergic acid diethylamide) by the addition of a propionyl (-CO-CH₂-CH₃) group at the nitrogen-1 (N1) position of the ergoline scaffold. This N1-acyl modification is the defining structural feature of the 1P-LSD molecule and the basis for its classification as a lysergamide prodrug in published in-vitro hydrolysis studies, where deacylation yields the parent lysergamide under physiological conditions. Authentic 1P-LSD reference standards with confirmed N1-propionyl substitution are therefore essential for forensic laboratories that must distinguish the analogue from its metabolites and from structurally related N1-acyl homologues including 1cP-LSD (cyclopropanecarbonyl), 1B-LSD (butanoyl), and 1V-LSD (valeryl). 1P-LSD for sale at UltraRawz ships worldwide with discreet packaging from our Europe and Netherlands warehouses.
1P-LSD is available at ultrarawz.com/shop in standard blotter format (100μg per blotter) with multiple quantity options. Each batch is HPLC-verified at ≥98% purity with batch-specific COA documentation. Related N1-acyl lysergamide research compounds available at UltraRawz include 1cP-LSD, 1B-LSD, 1V-LSD “Valerie”, 1D-LSD, AL-LAD, and LSZ — providing a comprehensive lysergamide reference panel for comparative analytical research. Browse the full catalog at ultrarawz.com — Lysergamides.
Chemical Identity & Classification
1P-LSD carries CAS number 2349352-11-2, molecular formula C₂₃H₂₉N₃O₂, and molecular weight 379.50 g/mol. Systematic IUPAC designation: 1-propanoyl-N,N-diethyl-d-lysergamide. Laboratory synonyms: 1-propionyl-LSD, 1P-LSD, 1-propionyllysergic acid diethylamide. Structurally classified as an N1-acyl ergoline lysergamide — featuring the tetracyclic ergoline scaffold with N,N-diethyl amide group at C-8 and propionyl substitution at N1. The N1-propionyl group increases molecular weight by 56 Da relative to LSD (MW 323.43 g/mol), providing a clean LC-MS/MS mass delta enabling discrimination from the parent compound and from other N1-acyl homologues (1cP-LSD MW 391.47, 1B-LSD MW 393.50, 1V-LSD MW 407.53). PubChem CID: 131823399. Protonated molecular ion [M+H]⁺: m/z 380.
Chemical & Physical Characteristics
1P-LSD is supplied in blotter substrate (standard laboratory blotter paper, 100μg per unit) with characteristic ergoline UV fluorescence (excitation 325 nm, emission 445 nm). The compound is highly photosensitive — among the most light-sensitive research compounds in the NPS catalog — requiring strict UV and visible light protection during all handling and storage operations. Aqueous solubility: moderate (ergoline scaffold). Methanol and ethanol: soluble. DMSO: soluble (≥10 mg/mL, free base equivalent). LogP: ~2.3 (calculated). UV absorption: strong at ~254 nm (indole chromophore) and 313 nm. The fluorescence emission at 445 nm is diagnostically useful for HPLC-FLD detection at sub-nanogram concentrations — a key advantage over UV-only detection for trace-level analytical work in biological matrices. Thermal stability: limited — more thermolabile than most NPS compounds, requiring strict cold chain storage.
Purity & Analytical Verification
Production lots certify ≥98% purity by gradient HPLC (C18 reverse-phase, acetonitrile/0.1% formic acid gradient, UV detection 254 nm, area normalization). Identity confirmed by: ¹H NMR (CDCl₃) showing characteristic ergoline indole proton signals at δ 7.1–8.2 ppm and propionyl CH₂ signals at δ 2.4–2.6 ppm (distinguishing 1P-LSD from 1cP-LSD cyclopropyl signals, 1B-LSD butanoyl CH₂ pattern, and 1V-LSD valeryl chain). LC-MS/MS identity: [M+H]⁺ at m/z 380; fragment at m/z 324 (loss of propionyl, 56 Da) identifying the N1-propionyl acyl group; further fragmentation at m/z 267, m/z 223 consistent with ergoline scaffold fragmentation. HPLC-FLD confirmation: excitation 325 nm, emission 445 nm. Karl Fischer water content: <0.5% w/w. Batch-specific COA available on request at support@ultrarawz.com.
Quality Control & Batch Integrity
Each 1P-LSD production batch undergoes specific stability-focused quality verification given the compound’s light and heat sensitivity: HPLC purity under amber light conditions, ¹H NMR identity confirmation, LC-MS/MS molecular ion and N1-acyl fragment verification, HPLC-FLD fluorescence response factor calibration, and visual blotter uniformity inspection. Blotter content uniformity testing (10 blotter sample, CV% <5% target) ensures consistent loading across the batch. Photostability testing confirms UV degradation susceptibility — batches demonstrating photostability failures are rejected. Cold chain handling throughout production and fulfillment maintains compound integrity from synthesis to delivery. All lots retain reference blotters for stability monitoring and reanalysis capability.
Safety, Handling & Laboratory Precautions
Handle exclusively under amber/red laboratory lighting to minimize photodegradation during operational procedures. Required PPE: nitrile gloves (double-glove), lab coat, safety glasses. Serotonin receptor agonist — prevent all dermal contact; verify glove integrity. Keep containers closed and return to cold storage immediately after use. Blotter handling: use clean forceps for blotter transfer — do not handle blotters with bare fingers (dermal absorption risk, potential substrate contamination). Aqueous stock solution preparation from blotters: extract in acidified methanol (0.1% formic acid) or DMSO, vortex 15 minutes, centrifuge to clarify. Anti-static forceps recommended for accurate blotter weighing. Spill: absorb with inert material, collect in sealed container, dispose per institutional chemical waste protocols. Emergency procedures: if skin contact, wash thoroughly with soap and water; if eye contact, flush 15 minutes and seek medical attention.
Packaging, Labeling & Storage
1P-LSD blotters are packaged in foil-sealed, opaque pouches with desiccant packs, in discreet external packaging. Each unit labeled with compound name, CAS number, lot number, purity, unit dose, and research use notice. Critical storage requirements for lysergamides: -20°C or below for long-term storage (>2 weeks) — more stringent than most research compounds due to higher thermolability. Short-term active use: ≤4°C (refrigerator), maximum 1 week. Protect from ALL light sources — UV and visible light. Maintain in sealed opaque foil pouch at all times when not in active analytical use. Inert gas headspace (nitrogen or argon purge) recommended for opened containers intended for extended use. Avoid alkaline conditions — ergoline scaffold shows accelerated degradation at pH >8. Under recommended storage conditions, stability maintained for the lot expiry period stated on the COA.
Intended Research Use & Market Positioning
1P-LSD research chemical is positioned as a primary reference standard for: forensic toxicology laboratories developing LC-MS/MS identification and quantitation methods for N1-acyl lysergamide detection in biological matrices and seized materials; 5-HT₂A, 5-HT₂B, and 5-HT₁A receptor binding studies examining comparative affinity profiles across the N1-acyl lysergamide compound class; N1-acyl prodrug hydrolysis kinetics research characterizing conversion rates to parent lysergamide under physiological conditions; HPLC-FLD and LC-HRMS method development for trace-level lysergamide analysis at sub-nanogram per milliliter concentrations; and comparative SAR programs examining how acyl group chain length and structure (propionyl vs cyclopropanecarbonyl vs butanoyl) modulates receptor selectivity and metabolic stability. Browse the complete lysergamide research panel at ultrarawz.com — Lysergamides.
Ordering, Availability & Fulfillment
1P-LSD is available in blotter format (100μg per blotter) in multiple quantity tiers — see product variants above for current pricing. Payment methods: Bitcoin (BTC), bank transfer, Apple Pay (Europe), Zelle (Europe), Revolut (Europe), gift cards — full details at ultrarawz.com/payment. Cold chain handling protocols applied during packing and dispatch to maintain compound integrity during transit. Orders processed same day with discreet, tamper-evident external packaging. Worldwide shipping from Europe and Netherlands warehouses. Typical delivery: 2–5 business days (Europe/EU); 5–10 business days international. Bulk research quantities and institutional COA requests: support@ultrarawz.com or WhatsApp +1 (567) 457-7456. Track at ultrarawz.com/track-order.
Legal & Regulatory Disclaimer
1P-LSD (CAS 2349352-11-2) is supplied strictly for laboratory research purposes only. Not for human or veterinary use. Not for clinical, diagnostic, or consumptive applications. Legal status varies significantly by jurisdiction — N1-acyl LSD analogues are controlled substances in many countries including the UK (under the Psychoactive Substances Act), Germany, Switzerland, and others. Purchasers are solely responsible for verifying and complying with all applicable regulations prior to ordering. UltraRawz supplies this compound exclusively to qualified research professionals for legitimate laboratory research purposes.
Frequently Asked Questions
Q: What is the structural difference between 1P-LSD and LSD?
A: 1P-LSD has a propionyl group (-CO-CH₂-CH₃) added at the N1 position of the ergoline scaffold. This adds 56 Da to the molecular weight (LSD MW 323.43 vs 1P-LSD MW 379.50) and produces a distinct LC-MS/MS fragment at m/z 324 (loss of propionyl group) that confirms N1-propionyl substitution. In published in-vitro hydrolysis studies, 1P-LSD undergoes deacylation to yield LSD under physiological conditions.
Q: How do I distinguish 1P-LSD from 1cP-LSD by LC-MS/MS?
A: The molecular ion difference: 1P-LSD [M+H]⁺ m/z 380 vs 1cP-LSD [M+H]⁺ m/z 392 (12 Da difference — cyclopropanecarbonyl vs propionyl acyl group). The neutral loss fragment also differs: 1P-LSD shows loss of 56 Da (propionyl) vs 1cP-LSD loss of 68 Da (cyclopropanecarbonyl). These mass deltas are sufficient for unambiguous discrimination in unit-resolution MS; HRMS provides additional confirmation via exact mass.
Q: Why does 1P-LSD require stricter storage than most research compounds?
A: The ergoline scaffold is more thermolabile and photosensitive than most NPS compounds. Published stability data shows significant degradation at room temperature over days and rapid photodegradation under laboratory lighting. Cold chain storage (-20°C or below) and strict light exclusion are essential for maintaining compound integrity and ensuring consistent analytical results across experimental sessions.
Q: What purity does UltraRawz 1P-LSD achieve?
A: ≥98% by HPLC area normalization. Batch-specific COA with HPLC chromatogram and NMR data available on request.
Q: What blotter load is supplied?
A: 100μg per blotter, standard format. Blotter content uniformity tested per batch (CV% <5% target across 10-blotter sample).
Q: Can I get a COA before purchasing?
A: Yes. Contact support@ultrarawz.com to request current lot COA documentation prior to purchase.
Q: What related lysergamides does UltraRawz carry?
A: We carry a full N1-acyl lysergamide research panel including 1cP-LSD, 1B-LSD, 1V-LSD “Valerie”, 1D-LSD, AL-LAD, LSZ, and 1cP-AL-LAD. Browse at ultrarawz.com — Lysergamides.
Q: Do you ship internationally?
A: Yes, worldwide from Europe and Netherlands warehouses. Legal status of N1-acyl lysergamides varies significantly by country — purchasers must verify local regulations before ordering. See shipping & delivery for details.
You must be logged in to post a review.

Reviews
There are no reviews yet.